L3 Campus Stackable Managed Switch

"

Especificacions

  • Model: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    LED
  • Indicació LED:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      correctament)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Instruccions d'ús del producte

Capítol 2: Instal·lació

Abans d'iniciar el procés d'instal·lació, assegureu-vos que ho teniu tot
the necessary tools and follow safety precautions.

  • Contingut del paquet: Check all items mentioned in
    el paquet.
  • Precaucions de seguretat: Follow the guidelines to
    garantir una instal·lació segura.
  • Eines d'instal·lació: Gather all tools required
    per a la instal·lació.
  • Instal·lació del producte: Seguiu el pas a pas
    instructions provided in the manual for successful
    instal·lació.

Capítol 3: Connexió

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Capítol 4: Configuració

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
necessitats.

Preguntes freqüents

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
secció del manual per obtenir més ajuda.

"`

Solució de xarxes empresarials
Guia d'instal·lació
Omada C.ampus Stackable L3 Managed Switch

Quant a aquesta guia d'instal·lació
Aquesta Guia d'instal·lació descriu les característiques del maquinari, els mètodes d'instal·lació i els punts que s'han de tenir en compte durant la instal·lació. Aquesta Guia d'instal·lació s'estructura de la següent manera: Capítol 1 Introducció Aquest capítol descriu els components externs de l'interruptor. Capítol 2 Instal·lació Aquest capítol il·lustra com instal·lar l'interruptor. Capítol 3 Connexió Aquest capítol il·lustra com fer la connexió física de l'interruptor. Capítol 4 Configuració Aquest capítol il·lustra com configurar l'interruptor. Apèndix A Resolució de problemes Apèndix B Especificacions

Públic

Aquesta guia d'instal·lació és per a:

Enginyer de xarxes

Administrador de xarxa

Convencions
· Alguns models que apareixen en aquesta guia poden no estar disponibles al vostre país o regió. Per obtenir informació sobre vendes locals, visiteu https://www.omadanetworks.com/.
· Les xifres del capítol 2, 3 i 4 només tenen finalitats demostratives. El vostre interruptor pot diferir en aparença del que es mostra.
· Els càlculs pressupostaris de PoE es basen en proves de laboratori. El pressupost d'alimentació PoE real no està garantit i variarà com a resultat de les limitacions del client i dels factors ambientals.
· Aquesta guia utilitza els formats específics per destacar missatges especials. La taula següent enumera les icones d'avís que s'utilitzen al llarg d'aquesta guia.

Recordeu que cal anar amb compte. Una precaució indica un potencial que pot provocar danys al dispositiu.
Recordeu que heu de notar-ho. La nota conté la informació útil per a un millor ús del producte.

Document relacionat
La Guia de l'usuari i la Guia de referència de la CLI del producte es proporcionen al Centre de descàrregues. Per obtenir la informació més recent sobre el producte, visiteu l’oficial weblloc web: https://support.omadanetworks.com/document/.

Continguts
Capítol 1 Introducció ———————- 01
1.1 Producte acabatview …………………………………………………………..01 1.2 Aspecte………………………………………………………………………..01
Capítol 2 Instal·lació ———————- 12
2.1 Contingut del paquet ………………………………………………………….12 2.2 Precaucions de seguretat …………………………………………………12 2.3 Eines d'instal·lació……………………………………………………..14 2.4 Instal·lació del producte ……………………………………………..14
Capítol 3 Connexió ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Capítol 4 Configuració ——————– 27
4.1 Configuració acabadaview…………………………………………27 4.2 Mode autònom……………………………………………………27 4.3 Mode de controlador ………………………………………………………28
Apèndix A Resolució de problemes —————- 32
Apèndix B Especificacions —————— 33

Omada C.ampus Stackable L3 Managed Switch

Capítol 1 Introducció

1.1 Producte acabatview
Dissenyat per a empreses i campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. ExampEls fitxers inclouen l'alimentació de càmeres de xarxa, punts d'accés a LAN sense fil, telèfons IP, concentradors de xarxa, ordinadors incrustats, etc.
1.2 Aparença
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Botó de selecció de mode
Port de gestió

LED

Console Port USB2.0 Port (Type-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Botó de selecció de mode
Port de gestió

LED

Console Port USB2.0 Port (Type-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

Introducció 01

Omada C.ampus Stackable L3 Managed Switch

Indicació LED

PWR1*

PWR2

Verd encès

Apagat

Verd encès

Groc activat**

Apagat

Verd encès

Apagat

Apagat

Indicació
L'interruptor és alimentat per PWR1. PWR2 està desconnectat o no funciona correctament.
L'interruptor és alimentat per PWR1. PWR1 i PWR2 estan connectats.*
L'interruptor és alimentat per PWR2. PWR1 està desconnectat o no funciona correctament.
L'interruptor està apagat o tant PWR1 com PWR2 funcionen incorrectament.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Quan el LED STK està encès)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Indicació
Parpellejant: l'interruptor funciona correctament. Encès o apagat: l'interruptor no funciona correctament.
Verd encès: tots els ventiladors funcionen correctament. Groc activat: no tots els ventiladors funcionen correctament.
Encès: Hi ha un dispositiu connectat al port. Intermitent: Transmetent o rebent dades. Apagat: No hi ha cap dispositiu connectat al port.
Activat: El dispositiu funciona com a interruptor principal en la topologia de pila o funciona individualment. Desactivat: El dispositiu funciona com a interruptor membre en la topologia de pila.
Verd activat: funciona a 1000 Mbps, però sense activitat. Verd intermitent: funciona a 1000 Mbps i transmet o rebuda dades. Groc activat: funciona a 10 Mbps/100 Mbps, però sense activitat. Groc intermitent: funciona a 10 Mbps/100 Mbps i transmet o rebuda dades. Apagat: no hi ha cap dispositiu enllaçat al port corresponent.
Activat: el número de port indica l'ID de la unitat a la topologia de la pila.
Verd activat: funciona a 10 Gbps, però sense activitat. Verd intermitent: funciona a 10 Gbps i transmet o rebuda dades. Groc activat: funciona a 1 Gbps, però sense activitat. Groc intermitent: funciona a 1 Gbps i transmet o rebuda dades. Apagat: no hi ha cap dispositiu enllaçat al port corresponent.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Quan tant PWR1 com PWR2 funcionen correctament i l'interruptor està alimentat per PWR1, el LED PWR10 (groc) triga entre 20 i 2 segons a apagar-se després de desconnectar el PWR2.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Introducció

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Botó de selecció de mode
Port de gestió
LED Console Port USB2.0 Port (Type-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

El panell frontal de l'S6500-48GP6XF es mostra a la figura següent.

Botó de selecció de mode
Port de gestió
LED Console Port USB2.0 Port (Type-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Botó de selecció de mode
Port de gestió
LED Console Port USB2.0 Port (Type-C/RJ45)

Port RJ2.5 45G

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Botó de selecció de mode
Port de gestió
LED Console Port USB2.0 Port (Type-C/RJ45)

Port RJ2.5 45G

25G SFP28 Slot LED

Introducció 03

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Botó de selecció de mode
Port de gestió

LED Console Port USB2.0 Port (Type-C/RJ45)

Port RJ2.5 45G

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Botó de selecció de mode
Port de gestió
LED Console Port USB2.0 Port (Type-C/RJ45)

Port RJ2.5 45G

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Indicació
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Parpellejant: l'interruptor funciona correctament. Encès o apagat: l'interruptor no funciona correctament.
Verd encès: tots els ventiladors funcionen correctament. Groc activat: no tots els ventiladors funcionen correctament.
Encès: la potència PoE restant és de 7 W. Parpellejant: la potència PoE restant manté 7 W després que aquest LED estigui encès durant 2 minuts. Apagat: la potència PoE restant és > 7 W.
Encès: Hi ha un dispositiu connectat al port. Intermitent: Transmetent o rebent dades. Apagat: No hi ha cap dispositiu connectat al port.
Activat: El dispositiu funciona com a interruptor principal en la topologia de pila o funciona individualment. Desactivat: El dispositiu funciona com a interruptor membre en la topologia de pila.

04 Introducció

Omada C.ampus Stackable L3 Managed Switch

LED

Indicació

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Verd activat: funciona a 1000 Mbps, però sense activitat. Verd intermitent: funciona a 1000 Mbps i transmet o rebuda dades. Groc activat: funciona a 10 Mbps/100 Mbps, però sense activitat. Groc intermitent: funciona a 10 Mbps/100 Mbps i transmet o rebuda dades. Apagat: no hi ha cap dispositiu enllaçat al port corresponent.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Quan el LED STK està encès)

Activat: el número de port indica l'ID de la unitat a la topologia de la pila.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Quan el LED PoE està encès)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Verd activat: funciona a 10 Gbps, però sense activitat. Verd intermitent: funciona a 10 Gbps i transmet o rebuda dades. Groc activat: funciona a 1 Gbps, però sense activitat. Groc intermitent: funciona a 1 Gbps i transmet o rebuda dades. Apagat: no hi ha cap dispositiu enllaçat al port corresponent.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Verd encès: Funcionant a 25 Gbps, però sense activitat. Verd intermitent: Funcionant a 25 Gbps i transmetent o rebent dades. Groc encès: Funcionant a 1 Gbps/10 Gbps, però sense activitat. Groc intermitent: Funcionant a 1 Gbps/10 Gbps i transmetent o rebent dades. Apagat: No hi ha cap dispositiu connectat al port corresponent.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Introducció 05

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Port de gestió

LED

Console Port USB3.0 Port

(RJ45/Tipus C)

Selecció del mode

Botó

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Botó de selecció de mode
Port de gestió
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Port de gestió

LED

Port USB 3.0

Port de la consola

(RJ45/Tipus C)

Botó de selecció de mode

Ranura SFP25 de 28G

LED

(Port 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

Ranura QSFP100 de 28G (Port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Introducció

Ranura QSFP100 de 28G (Port 49-56)

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Botó de selecció de mode
LED de port de gestió
Port USB 3.0

Console Port (Type-C/RJ45)

Ranura QSFP100 de 28G

LED

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
VENTILADOR SYS
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Quan el LED SPD està encès)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Indicació
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Parpellejant: l'interruptor funciona correctament. Encès o apagat: l'interruptor no funciona correctament.
Verd: tots els ventiladors funcionen correctament. Groc: no tots els ventiladors funcionen correctament.
Encès: Hi ha un dispositiu connectat al port. Intermitent: Transmetent o rebent dades. Apagat: No hi ha cap dispositiu connectat al port.
Nota:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Activat: El dispositiu funciona com a interruptor principal en la topologia de pila o funciona individualment. Desactivat: El dispositiu funciona com a interruptor membre en la topologia de pila.
Verd activat: funciona a 10 Gbps, però sense activitat. Verd intermitent: funciona a 10 Gbps i transmet o rebuda dades. Groc activat: funciona a 1 Gbps, però sense activitat. Groc intermitent: funciona a 1 Gbps i transmet o rebuda dades. Apagat: no hi ha cap dispositiu enllaçat al port corresponent.
Verd encès: Funcionant a 25 Gbps, però sense activitat. Verd intermitent: Funcionant a 25 Gbps i transmetent o rebent dades. Groc encès: Funcionant a 1 Gbps/10 Gbps, però sense activitat. Groc intermitent: Funcionant a 1 Gbps/10 Gbps i transmetent o rebent dades. Apagat: No hi ha cap dispositiu connectat al port corresponent.

Introducció 07

Omada C.ampus Stackable L3 Managed Switch

LED

Indicació

Port 27-32 of S7500-26XF6Y ***
(Quan el LED SPD està encès)

Verd encès: Funcionant a 25 Gbps, però sense activitat. Verd intermitent: Funcionant a 25 Gbps i transmetent o rebent dades. Groc encès: Funcionant a 1 Gbps/10 Gbps, però sense activitat. Groc intermitent: Funcionant a 1 Gbps/10 Gbps i transmetent o rebent dades. Apagat: No hi ha cap dispositiu connectat al port corresponent.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Verd activat: funciona a 100 Gbps, però sense activitat. Verd intermitent: funciona a 100 Gbps i transmet o rebuda dades. Groc activat: funciona a 40 Gbps, però sense activitat. Groc intermitent: funciona a 40 Gbps i transmet o rebuda dades. Apagat: no hi ha cap dispositiu enllaçat al port corresponent.
Nota:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Quan el LED STK està encès)

Activat: el número de port indica l'ID de la unitat a la topologia de la pila.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Port de gestió Dissenyat per connectar el dispositiu per a la gestió a través de web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Introducció

Omada C.ampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Model

1000M

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Ranura

Ranura

Port

Port Port

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Nota: PWR1 és la font d'alimentació principal i té prioritat sobre PWR2.

Introducció 09

Omada C.ampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Ranura de seguretat Kensington

LED

Terminal de terra

Mòdul d’alimentació

LED

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Terminal de terra

LED

Power Supply Module Locking Strap Slot

LED

Ranura de seguretat Kensington

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

El panell posterior de l'S7500-48Y8C es mostra a la figura següent. La figura només té finalitats demostratives. El vostre commutador pot tenir un aspecte diferent del que es mostra a la imatge.

Terminal de terra

LED

LED

Corretja de bloqueig

Ranura

Mòdul d’alimentació

10 Introducció

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada C.ampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED LED
Locking Strap Slot
Mòdul d'alimentació Ranura de seguretat Kensington

Terminal de terra

LED
Locking Strap Slot

Mòdul d’alimentació

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Introducció 11

Omada C.ampus Stackable L3 Managed Switch

Capítol 2 Instal·lació

2.1 Contingut del paquet

Assegureu-vos que el paquet contingui els elements següents. Si us plau, poseu-vos en contacte amb el vostre distribuïdor, si algun dels articles enumerats està danyat o falta. Les xifres són només per a demostració. Els articles reals poden diferir en aparença i quantitat dels representats.

Canvia

Cable d'alimentació i cable de consola

Guia d'instal·lació
Solució de xarxes empresarials
Guia d'instal·lació
Omada C.ampus Stackable L3 Managed Switch

Suports de muntatge, cargols i peus de goma

2.2 Precaucions de seguretat
Per evitar qualsevol dany al dispositiu i lesions corporals causades per un ús inadequat, heu d'observar les normes següents.
Precaucions de seguretat Mantingueu l'alimentació apagada durant la instal·lació. Porteu una corretja de canell antielectròstatiques electrostàtiques i assegureu-vos que tingui bon contacte amb la pell i que estigui ben
ben connectat a terra. Feu servir només el cable d'alimentació que s'inclou amb l'interruptor. Assegureu-vos que el voltatge de subministramenttage coincideix amb les especificacions indicades al panell posterior del
interruptor. Assegureu-vos que l'interruptor estigui instal·lat en un entorn ben ventilat i que el seu orifici de ventilació no
bloquejat. No obriu ni traieu la coberta de l'interruptor. Abans de netejar el dispositiu, talleu l'alimentació. No el netegeu amb el drap aquàtic, i mai
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Requisits del lloc
Temperatura/Humitat

12 Instal·lació

Omada C.ampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
La pols acumulada a l'interruptor pot ser absorbida per l'electricitat estàtica i provocar un mal contacte dels punts de contacte metàl·lics. S'han pres algunes mesures perquè el dispositiu eviti l'electricitat estàtica, però l'electricitat estàtica massa forta pot causar danys mortals als elements electrònics de la placa de circuit interna. Per evitar l'efecte de l'electricitat estàtica en el funcionament de l'interruptor, doneu molta importància als elements següents: Espolseu el dispositiu amb regularitat i manteniu l'aire interior net. Mantingueu el dispositiu ben connectat a terra i assegureu-vos que s'ha transferit l'electricitat estàtica. Interferència electromagnètica
Els elements electrònics que inclouen la capacitat i la inductància del dispositiu es poden veure afectats per interferències externes, com ara l'emissió conduïda per acoblament de capacitat, acoblament d'inductància i acoblament d'impedància. Per reduir les interferències, assegureu-vos de prendre les mesures següents: Utilitzeu la font d'alimentació que pugui filtrar eficaçment les interferències de la xarxa elèctrica. Manteniu el dispositiu lluny dels dispositius d'alta freqüència i corrent fort, com ara la transmissió de ràdio
estació. Utilitzeu blindatge electromagnètic quan sigui necessari. Protecció contra llamps
Instal·lació 13

Omada C.ampus Stackable L3 Managed Switch
Vol extremadament alttagEls corrents es poden produir a l'instant quan es produeix un llamp i l'aire de la ruta de descàrrega elèctrica es pot escalfar a l'instant fins a 20,000 °C. Com que aquest corrent instantani és prou fort com per danyar els dispositius electrònics, s'han de prendre mesures de protecció contra llamps més efectives. Assegureu-vos que el bastidor i el dispositiu estiguin ben connectats a terra. Assegureu-vos que la presa de corrent tingui un bon contacte amb el terra. Mantingueu un sistema de cablejat raonable i eviteu els llamps induïts. Utilitzeu el senyal SPD (dispositiu de protecció contra sobretensions) quan feu el cablejat a l'exterior.
Nota: Per obtenir mesures detallades de protecció contra llamps, consulteu la Guia de protecció contra llamps de: https://support.omadanetworks.com/r/1004/. Lloc d'instal·lació
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Eines d'instal·lació
Tornavisos Phillips Cables d'embolcall preventiu per a ESD
Nota: aquestes eines no estan incloses amb el nostre producte. Si cal, podeu comprar-los per separat.
2.4 Instal·lació del producte
L'interruptor està dissenyat amb una funció de dissipació de calor d'anterior a posterior. Quan funciona, l'aire circula com es mostra a continuació. Per a una millor dissipació de la calor, instal·leu el dispositiu en un entorn ben ventilat i deixeu espais de 5 a 10 cm al voltant del dispositiu.
14 Instal·lació

Figura 2-1

Circulació d'aire

Omada C.ampus Stackable L3 Managed Switch

Instal·lació d'escriptori

Per instal·lar el dispositiu a l'escriptori, seguiu aquests passos:
1. Col·loqueu el dispositiu sobre una superfície plana prou resistent per suportar tot el pes del dispositiu amb tots els accessoris.

2. Traieu els papers adhesius de suport dels peus de goma.

3. Col·loqueu els peus de goma a la part inferior del dispositiu per evitar que llisqui quan es col·loqueu a l'escriptori.

Figura 2-2

Instal·lació d'escriptori

Peus inferior de l'osca del dispositiu

Instal·lació de rack

El paquet inclou 6 parells de suports de muntatge en bastidor diferents, les seves imatges es mostren a continuació i poden diferir dels productes reals.

Figura 2-3

Suports de muntatge

Grup de forats de cargol 2

Bracket D Bracket C Bracket B Bracket A

Grup de forats de cargol 1
Grup de forats de cargol 3

Parèntesi F

Screw Hole Group 4-2 (for device with 420mm depth)

Grup de forats de cargol 5

Forat de cargol

Grup 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Suport E

Instal·lació 15

Omada C.ampus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Mètode

Demostració

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Distància del bastidor
(For device with a depth of 380mm)

Distància del bastidor
(For device with a depth of 420mm)

Distància del bastidor
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Instal·lació

Omada C.ampus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Per instal·lar el dispositiu, seguiu les instruccions que es descriuen a continuació:

1. Attach the M6 nuts to the racks.

Figura 2-4

Fixació de femelles M6

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Figura 2-5

Instal·lació de suports als bastidors

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Instal·lació 17

Omada C.ampus Stackable L3 Managed Switch

Figura 2-6

Instal·lació de suports a l'interruptor

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Figura 2-7

Instal·lació de commutadors en bastidors

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Instal·lació

Omada C.ampus Stackable L3 Managed Switch

Instal·lació del mòdul d'alimentació

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Figura 2-8

Aspecte del mòdul d'alimentació

Connector del cable d'alimentació CA
FAN

Clips de retenció

Nansa d'extracció

LED

Locking Strap Slot Release Handle

Si necessiteu afegir un mòdul d'alimentació més, seguiu aquests passos:

1. Porteu una polsera preventiva d'ESD i assegureu-vos que tingui bon contacte amb la pell i que estigui ben connectada a terra.

2. Premeu la nansa d'extracció del mòdul amb una mà i subjecteu la part inferior del mòdul amb l'altra. Empenyeu suaument el mòdul cap a dins al llarg de la guia de la ranura.

3. Allibereu la nansa d'extracció per fixar el mòdul d'alimentació al seu lloc.

Figura 2-9

Instal·lació del mòdul de font d'alimentació

Mànec d'alliberament

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Porteu una polsera preventiva d'ESD i assegureu-vos que tingui bon contacte amb la pell i que estigui ben connectada a terra.
Instal·lació 19

Omada C.ampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Si necessiteu treure el mòdul d'alimentació, seguiu aquests passos:
1. Porteu una polsera preventiva d'ESD i assegureu-vos que tingui bon contacte amb la pell i que estigui ben connectada a terra.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Instal·lació del mòdul de ventilador
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Figura 2-11 Aspecte del mòdul del ventilador
LED

20 Instal·lació

Extraction Handle Retainer Clips Release Handle

Omada C.ampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
connectat a terra. 2. Premeu la nansa d'extracció del mòdul amb una mà i estireu-la fins que
El mòdul surt completament del xassís.
Figura 2-12 Extracció d'un mòdul de ventilador danyat
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Instal·lació 21

Omada C.ampus Stackable L3 Managed Switch

Capítol 3 Connexió

3.1 Port Ethernet

Connecteu un port Ethernet del commutador a l'ordinador mitjançant un cable RJ45 com es mostra a la figura següent.

Figura 3-1

Connexió del port RJ45

Port RJ45

Cable RJ45

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Figura 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Port de consola
La CLI (Interfície de línia d'ordres) us permet gestionar el commutador, de manera que podeu carregar la CLI després de connectar els PC o terminals al port de consola del commutador mitjançant un cable (es proporciona un cable de consola RJ45, mentre que no es proporciona un cable tipus C).
Connecteu el port de la consola RJ45 del dispositiu amb l'ordinador mitjançant el cable de la consola tal com es mostra a la figura següent.

22 Connexió

Figura 3-3

Connexió del port de la consola (RJ45).

Omada C.ampus Stackable L3 Managed Switch

Connecteu el port de la consola tipus C del dispositiu amb l'ordinador mitjançant el cable tipus C (no inclòs) tal com es mostra a la figura següent.

Figura 3-4

Connexió del port de la consola (USB).

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Verifiqueu la instal·lació
Després de completar la instal·lació, verifiqueu els elements següents: Hi ha d'haver entre 5 i 10 cm d'espai lliure al voltant del dispositiu per a la ventilació i assegureu-vos que el flux d'aire
és adequat. El voltage de la font d'alimentació compleix el requisit del vol d'entradatage del dispositiu. La presa de corrent, el dispositiu i el bastidor estan ben connectats a terra. El dispositiu està connectat correctament a altres dispositius de xarxa.
Connexió 23

Omada C.ampus Stackable L3 Managed Switch

3.5 Encès

Connecteu el connector femella del cable d'alimentació proporcionat a la presa d'alimentació del dispositiu i connecteu el connector positiu a una presa de corrent tal com es mostra a la figura següent. Assegureu-vos que el voltage de la font d'alimentació compleix el requisit del vol d'entradatage (100-240 V~ 50/60 Hz).

Figura 3-5

Connexió a la font d'alimentació

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Inicialització
Després d’engegar el dispositiu, comença l’autotest d’engegada. Una sèrie de proves s'executen automàticament per garantir que el dispositiu funcioni correctament. Durant aquest temps, els seus indicadors LED respondran en l'ordre següent:
1. L'indicador LED PWR s'encén tot el temps. El LED SYS i els indicadors LED de tots els ports es mantenen apagats.
2. Al cap d'un minut aproximadament, el LED SYS i els indicadors LED de tots els ports parpellejaran momentàniament i després s'apagaran.
3. Pocs segons després, l'indicador LED SYS parpellejarà, cosa que representa una inicialització satisfactòria.
3.7 Topologia de pila
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Canvia

Models compatibles

Quantitat

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Connexió

Omada C.ampus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Hi ha tres estructures de topologia de pila per a diferents escenaris, creeu la topologia adequada segons les vostres necessitats:

1. Topologia en cadena: la topologia en cadena és relativament senzilla i no requereix connexió per cable entre la primera i l'última unitat. És adequat per a l'apilament a llarga distància, però la seva fiabilitat és relativament baixa.

Figura 3-6

Topologia en cadena

Grup de ports d'apilament 2
Grup de ports d'apilament 1

2. Topologia en anell: la topologia en anell té una fiabilitat més alta en comparació amb la topologia en cadena. Quan es desconnecta una de les cadenes de la topologia en anell, la topologia en anell es converteix en una topologia en cadena, però tot el sistema de pila encara pot funcionar amb normalitat. La topologia d'anell requereix una connexió per cable entre la primera i l'última unitat, de manera que no és adequada per a l'apilament a llarga distància.

Figura 3-7

Topologia en anell

Grup de ports d'apilament 2

Grup de ports d'apilament 1

Connexió 25

Omada C.ampus Stackable L3 Managed Switch

3. Topologia en estrella: la topologia en estrella connecta els commutadors a un interruptor principal central, per tant, pot augmentar significativament la velocitat de reenviament de dades entre commutadors membres alhora que proporciona una gestió unificada.

Figura 3-8

Topologia en estrella

Grup de ports d'apilament 2

Grup de ports d'apilament 3

Grup de ports d'apilament 1

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Connexió

Omada C.ampus Stackable L3 Managed Switch

Capítol 4 Configuració

4.1 Configuració acabadaview
El commutador admet dues opcions de configuració:
Mode autònom: configureu i gestioneu l'interruptor individualment. Mode controlador: configureu i gestioneu els dispositius de xarxa de manera centralitzada. Es recomana a la
xarxa a gran escala, que consta de dispositius massius com ara punts d'accés, commutadors i passarel·les.
Nota: quan l'interruptor es canvia del mode autònom al mode del controlador, les configuracions del commutador es perdran. Per obtenir més informació, consulteu els documents relacionats al centre de descàrregues del nostre oficial weblloc web: https://support.omadanetworks.com/product/.

4.2 Mode autònom

En mode autònom, utilitzeu un ordinador per configurar i gestionar el commutador mitjançant la GUI (interfície gràfica d'usuari) o la CLI (interfície de línia d'ordres).

Figura 4-1

Topologia per al mode autònom

Canvia

PC

Utilitzant la GUI
1. Per accedir a la pàgina de gestió del commutador, assegureu-vos que el commutador i l'ordinador es trobin a la mateixa subxarxa. Obriu un navegador i escriviu l'adreça IP del commutador al camp d'adreça i, a continuació, premeu la tecla Retorn.
Si el commutador obté l'adreça IP del servidor DHCP (normalment una passarel·la), cerqueu l'adreça IP del commutador al servidor DHCP.
Si no, utilitzeu l'adreça IP predeterminada 192.168.0.1 per iniciar la pàgina de gestió del commutador.

2. La primera vegada que inicieu la sessió, configureu el nom d'usuari i la contrasenya per protegir millor la vostra xarxa i els vostres dispositius. Després d'això, el sistema us redirigirà automàticament a la interfície d'inici de sessió per autenticar-vos amb les credencials recentment creades.

3. Després d'un inici de sessió correcte, apareixerà la pàgina principal. Podeu fer clic als menús de la part superior i esquerra per configurar les funcions corresponents.
Per obtenir configuracions detallades, consulteu la Guia de l'usuari i la Guia CLI. Les guies es poden trobar al centre de descàrregues del nostre oficial weblloc web: https://support.omadanetworks.com/product/.
Ús de la CLI Configureu una connexió Telnet o SSH per accedir al commutador mitjançant la CLI.

Configuració 27

Omada C.ampus Stackable L3 Managed Switch

Utilitzeu el port de la consola per accedir al commutador. Quan utilitzeu el port de la consola, inicieu el programa d'emulació de terminal (com ara Hyper Terminal) a l'ordinador i configureu el programa d'emulació de terminal de la següent manera:

Velocitat de transmissió 38400 bps

Bits de dades 8

Paritat Cap

Bits d'aturada 1

Control de flux Cap

Per obtenir configuracions detallades, consulteu la Guia de l'usuari i la Guia CLI. Les guies es poden trobar al centre de descàrregues del nostre oficial weblloc web: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Mode controlador
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Figura 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Interruptor de passarel·la

Omada Pro Hardware Controller (C5300) EAP
28 Configuració

EAP

EAP

Clients

Omada C.ampus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Cerqueu l'adreça IP de la passarel·la. Obriu la línia d'ordres al vostre PC i introduïu ipconfig. A la llista de resultats, cerqueu la passarel·la predeterminada, que també és l'adreça IP de la passarel·la.
2. Llançament a web navegador i introduïu l'adreça IP de la passarel·la. Inicieu la sessió a la passarel·la web pàgina. A continuació, aneu a Xarxa > LAN > Llista de clients DHCP per trobar l'adreça IP del vostre controlador segons la seva adreça MAC.
3. Introduïu l'adreça IP del vostre controlador a la barra d'adreces per obrir-la web pàgina.
4. Al controlador Omada Pro web pàgina, seguiu l'assistent per completar la configuració ràpida.
5. Després de la configuració ràpida, apareix la pàgina d'inici de sessió. Introduïu el nom d'usuari i la contrasenya que heu creat i feu clic a Iniciar sessió. A continuació, podeu configurar el controlador.
6. Si voleu gestionar els dispositius de manera remota, seguiu els passos següents:
a. Assegureu-vos que l'accés al núvol estigui habilitat al vostre controlador. Per defecte, l'accés al núvol està habilitat. Assegureu-vos que el LED del núvol parpelleja lentament.

b. Llançament a web navegador i introduïu https://omada.tplinkcloud.com a la barra d'adreces. Introduïu el vostre ID de TP-Link i la vostra contrasenya per iniciar sessió. Feu clic a + Afegeix un controlador i seleccioneu Controlador de maquinari per afegir el vostre controlador. A continuació, podeu configurar encara més el controlador.

For more details, refer to the Installation Guide of C5300.

A través del controlador de programari Omada Pro

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Figura 4-3

Gestioneu la xarxa mitjançant Omada Pro Software Controller

Porta d'entrada

Canvia

Controlador

Controlador de programari Omada Pro AP

AP

AP

executant-se a l'ordinador amfitrió

Clients

Configuració 29

Omada C.ampus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web pàgina. Si no, feu clic a Inicia un navegador per gestionar la xarxa.
2. Al controlador Omada Pro web pàgina, seguiu l'assistent per completar la configuració ràpida.
3. Després de la configuració ràpida, apareix la pàgina d'inici de sessió. Introduïu el nom d'usuari i la contrasenya que heu creat i feu clic a Iniciar sessió. A continuació, podeu configurar el controlador.
4. Si voleu gestionar els dispositius de manera remota, seguiu els passos següents:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web pàgina, aneu a Configuració > Accés al núvol per habilitar l'accés al núvol i vincular el vostre ID de TP-Link. Si l'heu configurat a la configuració ràpida, ometeu aquest pas.
b. Llançament a web navegador i introduïu https://omada.tplinkcloud.com a la barra d'adreces. Introduïu el vostre ID de TP-Link i la vostra contrasenya per iniciar sessió. Apareixerà una llista de controladors que s'han vinculat amb el vostre ID de TP-Link. A continuació, podeu fer clic a Inicia per configurar encara més el controlador.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

A través del controlador basat en núvol Omada Pro

El controlador basat en núvol Omada Pro és una bona alternativa sense necessitat d'instal·lar el controlador de programari en un ordinador.

Les llicències s'han de comprar addicionalment.

Figura 4-4

Gestioneu la xarxa mitjançant Omada Pro Cloud-Based Controller

Núvol Omada

Porta d'entrada

Canvia

AP

AP

AP

AP

Clients
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web navegador i introduïu https://omada.tplinkcloud.com a la barra d'adreces. Inicieu la sessió amb
your TP-Link ID.
30 Configuració

Omada C.ampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Podeu iniciar el controlador per adoptar i gestionar dispositius. * Aplicació Omada Amb l'aplicació Omada, també podeu gestionar el controlador en un lloc local o remot a través del vostre dispositiu mòbil. Per obtenir les configuracions detallades, consulteu la Guia de l'usuari del controlador. La guia es pot trobar al centre de descàrregues de la nostra pàgina oficial weblloc web: https://support.omadanetworks.com/product/.
Configuració 31

Omada C.ampus Stackable L3 Managed Switch
Apèndix A Resolució de problemes
P1. Què puc fer si oblideu el nom d'usuari i la contrasenya del commutador?
1. Connecteu el port de consola de l'ordinador al port de consola de l'interruptor i obriu un programa d'emulació de terminal.
2. Apagueu i reinicieu l'interruptor. Realitzeu l'acció indicada pel programa d'emulació de terminal per arribar al menú bootUtil. L'acció és diferent d'un producte a un altre. Les accions possibles s'enumeren a continuació: · Premeu qualsevol tecla per aturar l'arrencada automàtica. · Premeu CTRL-B per accedir al menú bootUtil.
3. Es mostrarà el menú bootUtil. Introduïu el número 6 per seleccionar l'opció "Recuperació de contrasenya" i introduïu Y per eliminar tots els usuaris i contrasenyes. A continuació, podeu restablir el nom d'usuari i la contrasenya.
P2. Per què el LED PWR funciona de manera anormal? El LED PWR/Power hauria d'estar encès quan el sistema d'alimentació funciona normalment. Si el LED PWR/Power funciona de manera anormal, seguiu els passos següents:
1. Assegureu-vos que el cable d'alimentació estigui connectat correctament i que el contacte d'alimentació sigui normal. 2. Assegureu-vos que el voltatgetage de la font d'alimentació compleix el requisit del vol d'entradatage de la
interruptor.
P3. Què he de fer si no puc accedir a web pàgina de gestió? Prova el següent:
1. Comproveu tots els LED de port de l'interruptor i assegureu-vos que el cable Ethernet estigui connectat correctament. 2. Proveu amb un altre port de l'interruptor i assegureu-vos que el cable Ethernet sigui adequat i funcioni amb normalitat. 3. Apagueu l'interruptor i, al cap d'una estona, torneu-lo a encendre. 4. Assegureu-vos que l'adreça IP del vostre ordinador estigui configurada a la subxarxa del commutador. 5. Si encara no podeu accedir a la pàgina de configuració, restabliu el commutador als valors predeterminats de fàbrica. Aleshores
l'adreça IP del vostre ordinador s'hauria d'establir com a 192.168.0.x (“x” és qualsevol número del 2 al 254) i la màscara de subxarxa com a 255.255.255.0.
P4. Per què el programa d'emulació de terminal no es mostra correctament? Proveu el següent:
1. Assegureu-vos que la font d'alimentació sigui normal i que el cable de la consola estigui connectat correctament. 2. Comproveu si el cable de la consola és del tipus correcte. 3. Assegureu-vos que els paràmetres del programa d'emulació de terminal són correctes: configureu Bits per segon
com a 38400, bits de dades com a 8, paritat com a cap, bits de parada com a 1 i control de flux com a cap.
32 Apèndix A Resolució de problemes

Omada C.ampus Stackable L3 Managed Switch

Apèndix B Especificacions

Specifications for S6500 Series Switches

Item

Contingut

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Normes

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Apèndix B Especificacions 33

Omada C.ampus Stackable L3 Managed Switch

Pressupost PoE

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Temperatura i altitud de funcionament

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Temperatura d'emmagatzematge -40 °C a 70 °C (-40 °F a 158 °F)

Humitat de funcionament 10% a 90% HR Sense condensació

Humitat d'emmagatzematge

5% a 90% HR Sense condensació

34 Apèndix B Especificacions

Omada C.ampus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Item

Contingut

Normes

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

LED
Temperatura i altitud de funcionament

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Temperatura d'emmagatzematge -40 °C a 70 °C (-40 °F a 158 °F)

Humitat de funcionament 10% a 90% HR Sense condensació

Humitat d'emmagatzematge

5% a 90% HR Sense condensació

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
L'altitud admesa és des del nivell del mar fins als 5000 m. Cal tenir en compte que quan l'altitud és superior a 2000 m, per cada 220 metres d'augment d'altitud, la temperatura màxima de funcionament baixarà 1 °C (1.8 °F).

Apèndix B Especificacions 35

Omada C.ampus Stackable L3 Managed Switch

Especificacions dels mòduls d'alimentació

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Entrada de potència

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Vol. De sortidatage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Corrent de sortida

9.35 A (màxim)

16.5 A (màxim)

45 A (màxim)

Potència de sortida

500 W (màxim)

900 W (màxim)

550 W (màxim)

Altitud de funcionament

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 Apèndix B Especificacions

Advertència marca CE
Aquest és un producte de classe A. En un entorn domèstic, aquest producte pot causar interferències de ràdio, en aquest cas es pot demanar a l'usuari que prengui les mesures adequades.
Declaració de conformitat de la UE
TP-Link declara que el commutador compleix els requisits essencials i altres disposicions pertinents de les directives 2014/30/UE, 2014/35/UE, 2011/65/UE i (UE) 2015/863. ​​La Declaració de Conformitat UE original es pot trobar a https://www.tp-link.com/en/support/ce/
Declaració de conformitat del Regne Unit
TP-Link declara que l'interruptor compleix els requisits essencials i altres disposicions pertinents del Reglament de compatibilitat electromagnètica de 2016 i del Reglament d'equips elèctrics (seguretat) de 2016. La Declaració de conformitat original del Regne Unit es pot trobar a https://www.tp-link.com/support/ukca/
, .
PRECAUCIÓ:
Doble pol, fusió neutre. Desconnecteu la xarxa abans del servei.
Informació de seguretat
· Mantingueu el dispositiu allunyat de l'aigua, el foc, la humitat o els ambients calents. · No intenteu desmuntar, reparar o modificar el dispositiu. Si necessiteu servei, poseu-vos en contacte amb nosaltres. · Col·loqueu el dispositiu amb la superfície inferior cap avall. · L'endoll del cable d'alimentació s'utilitza com a dispositiu de desconnexió, la presa de corrent ho serà
fàcilment accessible. · Connecteu el producte a les preses de corrent amb connexió a terra a través del cable d'alimentació
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
bateries.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Si us plau, llegiu i seguiu la informació de seguretat anterior quan feu servir el dispositiu. No podem garantir que no es produeixin accidents o danys per un ús inadequat del dispositiu. Si us plau, utilitzeu aquest producte amb cura i feu-ho sota el vostre propi risc.

Per obtenir assistència tècnica, guies d'usuari i altra informació, visiteu https://support.omadanetworks.com/ o simplement escanegeu el codi QR.
© 2026 TP-Link 7100002759 REV2.0.1

Documents/Recursos

Omada L3 Campus Stackable Managed Switch [pdfManual d'usuari
L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch

Referències

Deixa un comentari

La teva adreça de correu electrònic no es publicarà. Els camps obligatoris estan marcats *