SoliTek SOLID Series Solar Modules Installation Guide

SoliTek-LOGO

SoliTek SOLID Series Solar Modules

SoliTek-SOLID-Series-Solar-Modules-PRODUCT

Instruccions d'ús

  • Read this guide entirely before installation.
  • This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
  • This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
  • All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
  • This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
  • It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
  • The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
  • Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
  • El no seguir les instruccions d'aquesta guia pot danyar els components del sistema, posar en perill el personal, danyar la propietat o invalidar la garantia del panell.
  • Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.

REQUISITS GENERALS

  • Si us plau, llegiu aquesta guia completament abans de la instal·lació.
  • L'objectiu d'aquest document és proporcionar requisits mínims i recomanacions per a una instal·lació segura i exitosa dels mòduls fotovoltaics SoliTek.
  • Aquest document també conté els requisits necessaris per mantenir el compliment del mòdul fotovoltaic SoliTek amb les normes IEC 61215, IEC 61730, UL 61730.
  • Aquesta guia conté informació bàsica sobre els mòduls fotovoltaics de la sèrie SOLID de JSC “SoliTek Cells”, la seva instal·lació i manipulació segura. Totes les instruccions s'han de llegir i entendre abans d'intentar la instal·lació. Si teniu cap pregunta, poseu-vos en contacte amb el vostre distribuïdor o amb JSC "SoliTek Cells" per obtenir més informació.
  • This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
  • It serves as a general but strictly mandatory reference for the Installer.
  • La infracció o l'observança inexacta de qualsevol clàusula d'aquesta documentació anul·la la garantia.
  • L'instal·lador ha d'entendre i seguir totes les regulacions i estàndards locals, estatals i federals aplicables per a la construcció d'edificis, disseny elèctric, incendis i seguretat, i ha de consultar amb les autoritats locals per determinar els requisits de permís aplicables abans d'intentar instal·lar o mantenir els mòduls fotovoltaics i hauria de familiaritzar-se amb els requisits mecànics i elèctrics dels sistemes fotovoltaics.
  • El fet de no seguir les instruccions d'aquesta guia pot danyar els components del sistema, posar en perill el personal, danyar la propietat o invalidar la garantia del panell.
  • Els sistemes fotovoltaics al terrat només s'han d'instal·lar en habitatges que hagin estat analitzats formalment per a la integritat estructural i que s'hagi confirmat que són capaços de manejar la càrrega ponderada addicional dels components del sistema fotovoltaic, inclosos els mòduls fotovoltaics, per un especialista o enginyer certificat en construcció.
  • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
  • For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
  • La construcció del mòdul fotovoltaic de placa plana consisteix en un conjunt laminat de cèl·lules solars encapsulades dins d'un material aïllant dins de dues làmines de vidre.
  • Guardeu aquesta documentació en un lloc segur per a futures consultes.
  • No intenteu desmuntar el mòdul i no traieu cap placa d'identificació o components adjuntats! Si ho feu, anul·larà la garantia.

Manipulació i aplicació

MANIPULACIÓ

  • SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
  • Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
  • No supereu l'alçada màxima dels palets a apilar, tal com s'indica a l'embalatge del palet.
  • Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
  • SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
  • Do not exert mechanical stress on the cables.
  • Never step on PV modules or drop or place heavy objects on them.
  • Be careful when placing PV modules on hard surfaces and secure them from falling.
  • Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
  • Broken or damaged PV modules must be handled carefully and disposed of properly.

APLICACIÓ

Restriccions

  • SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
  • PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
  • Do not install modules above 2000 m (6561 ft) altitude above sea level
  • La llum concentrada artificialment no s'ha de dirigir als mòduls fotovoltaics SoliTek.

Recomanacions

  • SoliTek recomana que els mòduls fotovoltaics es muntin amb un angle d'inclinació mínim de 10 graus per permetre una auto-neteja adequada de la pluja.
  • L'ombrejat parcial o complet d'un mòdul o mòduls fotovoltaics pot reduir significativament el rendiment del sistema.
  • SoliTek recomana minimitzar la quantitat d'ombra durant tot l'any per augmentar la quantitat d'energia produïda pels mòduls fotovoltaics.
  • Sistema alt voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
  • The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage creixements.
  • Una millor ventilació del mòdul i cables de connexió més curts augmenten la producció d'energia elèctrica.

Per als mòduls bifacials:

  • Es recomana augmentar l'alçada del panell fotovoltaic des del terra perquè més llum pugui viatjar per sota del mòdul i després reflectir-se
  • El guany bifacial augmenta significativament si els mòduls s'instal·len per sobre de superfícies blanques (alt valor d'albedo) que reflecteixen la llum.

Instal·lació elèctrica

SEGURETAT

  • Els mòduls fotovoltaics poden produir corrent i voltage quan s'exposa a la llum de qualsevol intensitat. El corrent elèctric augmenta amb la intensitat de la llum. DC voltage de 50 volts o més és potencialment letal. Contactar amb els circuits en viu d'un sistema fotovoltaic que funciona sota llum pot provocar una descàrrega elèctrica letal.
  • Desconnecteu els mòduls fotovoltaics traient-los completament de la llum o cobrint-ne la superfície frontal amb un material opac. Pel que fa a les normes de seguretat per a equips elèctrics amb corrent quan es treballa amb mòduls exposats a qualsevol llum. Utilitzeu eines aïllades i no porteu joies metàl·liques mentre treballeu amb mòduls fotovoltaics.
  • Per evitar arcs i descàrregues elèctriques, no desconnecteu les connexions elèctriques sota càrrega. Les connexions defectuoses també poden provocar arcs elèctrics i descàrregues elèctriques. Mantingueu els connectors secs i nets i assegureu-vos que funcionin correctament. No introduïu mai objectes metàl·lics als connectors ni els modifiqueu de cap manera per tal de garantir una connexió elèctrica.
  • Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
  • The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
  • La instal·lació de sistemes solars fotovoltaics requereix habilitats i coneixements especialitzats. Només ha de ser realitzat per personal qualificat i especialment instruït. L'instal·lador assumeix tots els riscos de lesions, inclòs el risc de descàrrega elèctrica.
  • Utilitzeu només equips, connectors, cablejat i maquinari de muntatge dissenyats específicament per al seu ús en un sistema fotovoltaic.
  • Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
  • Quan es desconnecten els cables connectats a un mòdul fotovoltaic que està exposat a la llum, es pot produir un arc elèctric. Els arcs poden provocar cremades, provocar incendis o, d'una altra manera, crear problemes de seguretat (fins a descàrregues elèctriques letals).
  • Comproveu el volum restanttage before starting and observe the local safety-relevant regulations for such working conditions.
  • En condicions normals, un mòdul fotovoltaic pot produir més corrent i/o voltage (aquí: 30 V CC) del que s'indica a les condicions de prova estàndard.
  • Contacte amb un DC voltage de 30 V o més és potencialment perillós. Aneu amb compte quan connecteu o manipuleu mòduls exposats a la llum solar.
  • Connecteu només mòduls amb el mateix corrent nominal de sortida en sèrie. Si els mòduls estan connectats en sèrie, el volum totaltage és igual a la suma del mòdul individual voltages.
  • Connecteu només mòduls o combinacions en sèrie de mòduls amb el mateix volumtage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
  • Utilitzeu sempre el mateix tipus de mòdul dins d'un sistema fotovoltaic concret.
  • If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
  • Utilitzar els equips de seguretat adequats (eines aïllants, guants dielèctrics, calçat, etc.) homologats per al seu ús en instal·lacions elèctriques.

CONFIGURACIÓ

  • En condicions normals, és probable que un mòdul fotovoltaic experimenti condicions que produeixen més corrent i/o volumtage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) s'ha de multiplicar per un factor de fins a 1.25 en funció de la temperatura ambient més baixa i més alta registrada per a la ubicació de la instal·lació quan es determina el volum del componenttage, classificacions de corrent del conductor, mides de fusibles i mida dels controls connectats a la sortida fotovoltaica.
  • VoltagSón additius quan els mòduls fotovoltaics es connecten directament en sèrie, i els corrents dels mòduls són additius quan els mòduls fotovoltaics estan connectats directament en paral·lel. Els mòduls fotovoltaics amb diferents característiques elèctriques no s'han de connectar directament en sèrie. L'ús de dispositius electrònics de tercers adequats connectats a mòduls fotovoltaics pot permetre diferents connexions elèctriques i s'ha d'instal·lar segons les instruccions especificades del fabricant.
  • El vol màximtage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. A més, el volum màxim d'entradatagS'ha de tenir en compte e de l'inversor i de la resta d'aparells elèctrics del sistema. El circuit obert voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
  • Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.

DISPOSITIU DE PROTECCIÓ CONTRA SOBRECORRENTS (OCPD)

  • When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
  • An overcurrent protection device is required for each series string if more than two series are connected in parallel.
  • In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
  • The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
  • Fusible amp valoració ≥ 1.25 x Isc
  • Seleccioneu la classificació estàndard més alta al catàleg de fusibles fotovoltaics disponibles.
  • Isc = Corrent de curtcircuit d'un mòdul en condicions de prova estàndard (STC).
  • Tenint en compte els valors d'Isc dels mòduls SoliTek, el valor correcte dels fusibles fotovoltaics a utilitzar a la instal·lació és de 30 A. SoliTek recomana utilitzar fusibles fotovoltaics tant en el conductor positiu com en el negatiu.

CABLE I CABLEJAT

Els mòduls fotovoltaics SoliTek es proporcionen amb dos cables de sortida estàndard resistents a la llum solar que s'acaben amb connectors fotovoltaics preparats per a la majoria d'instal·lacions. El terminal positiu (+) té un connector mascle mentre que el terminal negatiu (-) té un connector femella. El cablejat del mòdul està pensat per a connexions en sèrie (és a dir, interconnexions mascle (+) a femella (-)), però també es pot utilitzar per connectar dispositius elèctrics de tercers adequats que poden tenir configuracions de cablejat alternatives sempre que se segueixin les instruccions del fabricant.
Utilitzeu cablejat de camp amb àrees de secció transversal adequades que estiguin aprovades per al seu ús al corrent de curtcircuit màxim del mòdul fotovoltaic. Tot el cablejat ha de ser cables reticulats amb doble aïllament amb una potència mínima de 1,8 kV (més de 1500 V vol.tage) i una temperatura nominal mínima de 90 °C (190 °F). Mida del cable no inferior a 4 mm² (12 AWG). El tipus d'aïllament ha de ser adequat per al tipus de mètode d'instal·lació utilitzat i ha de complir els requisits de la IEC 61730 i la classe de seguretat II.

  • Nivell d'aïllament: 1,8 kV (conductor-conductor).
  • Temperatura: -40 °C fins a +90 °C (-40 °F fins a 190 °F) com a mínim.
  • Construcció del conductor: fil de coure llaunat amb una puresa de coure superior al 99,9%.
  • Aïllament primari: polietilè reticulat (XLPE), resistent a la llum solar i a la humitat, retardant de flama. Apte per a conductes i canals instal·lats sota terra.
  • Aïllament (jaqueta): termoplàstic, resistent a la llum solar, retardant de flama, resistent a l'aigua.
  • Diàmetre exterior mínim del cable amb aïllament: 5,2 mm (2,05 polzades).
  • Secció mínima del conductor: 4 mm² (12 AWG).

SoliTek recomana als instal·ladors que utilitzin només cables resistents a la llum solar qualificats per al cablejat de corrent continu (DC) en sistemes fotovoltaics. Els cables s'han de fixar a l'estructura de muntatge de manera que s'evitin danys mecànics al cable i/o al mòdul. No apliqueu tensions als cables. Per a la fixació, utilitzeu mitjans adequats, com ara brides de cable resistents a la llum solar i/o clips de gestió de cables. Tot i que els cables són resistents a la llum solar i impermeables, sempre que sigui possible, eviteu l'exposició directa a la llum solar i la immersió en aigua dels cables.
La longitud estàndard dels cables de les caixes de connexió és d'1,2 m (47,24 polzades). Es pretén que dos panells s'interconnectin en el sistema.

TERRENAMENT

  • Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:

Framed type modules grounding
Els forats marcats amb una marca de connexió a terra al marc només es poden utilitzar per a la connexió a terra. No perforeu forats de connexió a terra addicionals al marc del mòdul.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
El conductor de terra ha de fer una connexió a terra mitjançant un elèctrode de terra adequat.
A bolted connection is required; it incorporates:

  • Una mida de cargol de M4.
  • Una volandera dentada sota el cap del cargol o un cargol dentada ha de penetrar en recobriments no conductors com ara un marc anoditzat.
  • Una femella de fixació adequada per a cargols M4.
  • Tot el maquinari ha de ser de metall no fèrric, acer inoxidable de la sèrie 300 o adequadament protegit contra la corrosió.
  • El parell recomanat de bloqueig de la femella és de 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
  • El cargol de presa de terra ha de passar per tots els elements de connexió.

SoliTek-SOLID-Series-Solar-Modules-FIG-1

  • Els dispositius enumerats i identificats per a la posada a terra de marcs metàl·lics de mòduls fotovoltaics poden posar a terra els marcs metàl·lics exposats del mòdul a estructures de muntatge posades a terra.
  • In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
  • Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
  • Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.

Frameless type modules grounding

  • Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.

CONECTORS

  • Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
  • No intenteu fer una connexió elèctrica amb connectors humits, bruts o defectuosos.
  • Eviteu l'exposició a la llum solar i la immersió en aigua dels connectors. Eviteu connectors recolzats al terra o a la superfície del sostre.
  • Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
  • Comproveu que totes les connexions elèctriques estiguin ben fixades. Assegureu-vos que tots els connectors de bloqueig estiguin totalment connectats i bloquejats.

DIODES DE BYPASS

The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Els díodes de bypass no són dispositius de protecció contra sobreintensitat. Els díodes de bypass desvien el corrent de les cadenes de cèl·lules en cas d'ombrejat parcial. Característiques d'aquests díodes:

  • Voltage rating - 50 V.
  • Valoració actual: 25 A.

CLASSE DE FOC

  • Els mòduls SoliTek SOLID Bifacial i Blackstar han estat aprovats per la prova de resistència al foc IEC i han aconseguit la classe d'inflamabilitat A. La prova de resistència al foc es va realitzar amb una inclinació de 127 mm (5 polzades) per cada 300 mm (11,81 polzades), tal com es prescriu al punt A.2.5 de la norma IEC 61730-2.
  • SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.

Muntatge mecànic

  • The mechanical loads described in this manual are the test loads.
  • For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.

REQUISITS GENERALS

  • Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
  • Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
  • If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
  • Si us plau, observeu les normes de seguretat i les instruccions d'instal·lació incloses amb el sistema de muntatge. Si cal, poseu-vos en contacte directament amb el proveïdor per obtenir més informació.
  • The modules must be safely set onto the mounting rail.
  • The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
  • The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
  • Before installing modules on a roof, ensure that the roof construction is suitable.
  • In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
  • Assegureu-vos que el rail de muntatge no es deformi ni afecti els mòduls quan s'expandeixi com a conseqüència de l'expansió tèrmica.
  • The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
  • No intenteu perforar la superfície del vidre i els marcs dels mòduls, ja que això anul·larà la garantia.
  • The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.

Els components de muntatge han d'estar fets de materials duradors, anticorrosius i resistents als raigs UV (es recomana components d'acer inoxidable i alumini anoditzat).

MUNTATGE AMB CLAMPS

  • Utilitzar com a mínim 4 cl de laminatamps per fixar mòduls als rails de muntatge. Mòduls clampLes peces metàl·liques no han d'entrar en contacte amb el vidre frontal o posterior. En triar aquest tipus de clamp-Mètode de muntatge, utilitzeu almenys quatre clamps a cada mòdul; dos clamps s'han d'adjuntar a cada costat llarg. En funció de les càrregues locals de vent i neu, clampEs poden requerir s per garantir que els mòduls puguin suportar la càrrega.
  • ClampEl parell de tensió ha de ser d'almenys 15 Nm (11,06 ft-lb), però no superior a 20 Nm (14,75 ft-lb). Normalment, s'aconsegueix 15 Nm (11,06 ft-lb) quan dos productes d'aluminifilees toquen. Quan s'instal·la un mòdul en orientació vertical al sostre inclinat que té una inclinació superior a 45°, cal un ganxo addicional a la part inferior del mòdul.

SoliTek-SOLID-Series-Solar-Modules-FIG-2 SoliTek-SOLID-Series-Solar-Modules-FIG-3

SOLID Black, Semi-clear, Satin, Agro Frameless

Amb rails transversals

SoliTek-SOLID-Series-Solar-Modules-FIG-4 SoliTek-SOLID-Series-Solar-Modules-FIG-5SoliTek-SOLID-Series-Solar-Modules-FIG-6

BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting

  • En triar aquest tipus de clamp-Mètode de muntatge, utilitzeu almenys quatre clamps a cada mòdul; dos clamps s'han d'adjuntar a cada costat del mòdul. Mòduls clamps no ha d'entrar en contacte amb el vidre frontal i no ha de deformar el marc.
  • Assegureu-vos d'evitar efectes d'ombra a les cèl·lules solars del mòdul clamps.
  • The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
  • La longitud de clamp should be at least 30 mm (1,18 inch).
  • El clamp ha de superposar el marc del mòdul almenys 5 mm (0,2 polzades), però no més de 10 mm (0,4 polzades).

Amb rails transversals

SoliTek-SOLID-Series-Solar-Modules-FIG-7 SoliTek-SOLID-Series-Solar-Modules-FIG-8 SoliTek-SOLID-Series-Solar-Modules-FIG-9

Sense rails transversals o rails són perpendiculars al marc lateral llarg

SoliTek-SOLID-Series-Solar-Modules-FIG-10 SoliTek-SOLID-Series-Solar-Modules-FIG-11

Amb sistema d'inserció

SoliTek-SOLID-Series-Solar-Modules-FIG-12

Muntatge amb cargols

  • El mòdul s'ha de fixar i suportar amb quatre cargols d'acer inoxidable M8 a través dels forats de muntatge indicats a les barres transversals. Parell d'apretament al clamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
  • If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampS'ha de triar el maquinari.

SoliTek-SOLID-Series-Solar-Modules-FIG-13

  • Mounting with bolts can be done only through dedicated predrilled holes in the frame.
  • Perforar nous forats està prohibit i anul·larà la garantia.

SoliTek-SOLID-Series-Solar-Modules-FIG-14 SoliTek-SOLID-Series-Solar-Modules-FIG-15

POSICIÓ DE LA CAIXA DE CONNEXIÓ

  • Per a la distància entre la caixa de connexions i la vora del mòdul o altres dimensions de la posició i les àrees de la caixa de connexions, consulteu les figures que es mostren a continuació.

SoliTek-SOLID-Series-Solar-Modules-FIG-16

MANTENIMENT

  • Per tal d'assegurar un rendiment òptim del mòdul, SoliTek recomana el següent:
  • Si cal, la part frontal de vidre del mòdul es pot netejar amb aigua i una esponja o drap suau.
  • Es pot utilitzar un detergent suau i no abrasiu per eliminar les taques més tossudes.
  • Comproveu les connexions elèctriques i mecàniques periòdicament i assegureu-vos que estiguin netes, segures, completes i segures.
  • En cas d'un problema, consulteu amb una persona llicenciada/qualificada.

ESPECIFICACIONS

Paràmetre \ Model BLACKSTAR B.96 SOLID Black (Semi-Clear) B.96 35(40) mm BLACKSTAR Satin B.96 MAGNUS B.108
Condicions de prova STC STC STC STC
Potència nominal 455 W 455 W 445 W 510 W
Dades elèctriques @STC
Potència màxima (Pmax), W 455 455 445 510
Voltage a la potència màxima (Vmpp), V 29,71 29,71 29,40 33,34
Corrent a la potència màxima (Impp), A 15,31 15,31 15,14 15,30
Circuit obert Voltage (Voc), V 34,82 34,82 34,40 39,06
Corrent de curtcircuit (Isc), A 15,97 15,97 15,79 15,95
Dades tèrmiques
Interval de temperatura de funcionament -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F)
Coeficient de temperatura de Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F)
Coeficient de temperatura de Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F)
Coeficient de temperatura de Isc +0,036%/°C (°F) +0,036%/°C (°F) +0,036%/°C (°F) +0,036%/°C (°F)
Dades de mida i pes
Longitud 1762 mm 1762 mm 1762 mm 1961 mm
Amplada 1134 mm 1134 mm 1134 mm 1134 mm
Gruix 30 mm 35(40) mm 30 mm 30 mm
Pes 25,5 kg 35 (36) kg 25,5 kg 28,5 kg
Mètode de muntatge
Reference to the chapter 3.3 3.3 3.3 3.3
Altres
Corrent invers màxim, A 30
Fire    class, IEC 61730/UL 61730 A/Tipus II
Volum màxim del sistematage, V 1500

Table 9. Electrical and mechanical parameters table.

Paràmetre \ Model SÒLID Semi- clear B.96 SOLID Black B.96 SÒLID Satin B.96 SÒLID Agro B.64
Condicions de prova STC STC STC STC
Potència nominal 455 W 455 W 445 W 300 W
Dades elèctriques @STC
Potència màxima (Pmax), W 455 455 445 300
Voltage a la potència màxima (Vmpp), V 29,71 29,71 29,40 19,60
Corrent a la potència màxima (Impp), A 15,31 15,31 15,14 15,31
Circuit obert Voltage (Voc), V 34,82 34,82 34,40 22,76
Corrent de curtcircuit (Isc), A 15,97 15,97 15,79 15,97
Dades tèrmiques
Interval de temperatura de funcionament -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F)
Coeficient de temperatura de Pmax -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Coeficient de temperatura de Voc -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Coeficient de temperatura de Isc +0,045%/°C (°F) +0,045%/°C (°F) +0,045%/°C (°F) +0,045%/°C (°F)
Dades de mida i pes
Longitud 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm
Amplada 1144±2 1144±2 1144 ± 2 mm 1144 ± 2 mm
Gruix 7,2 mm 7,2 mm 7,2 mm 7,2 mm
Pes 33 kg 33 kg 33 kg 33 kg
Mètode de muntatge
Reference to the chapter 3.2 3.2 3.2 3.2
Altres
Corrent invers màxim, A 30
Fire    class, IEC 61730/UL 61730 A/Tipus II
Volum màxim del sistematage, V 1500

Table 10. Electrical and mechanical parameters table.

Paràmetre \ Model SOLID Satin B.96 35 mm SOLID Satin B. 96 40 mm SOLID AgroB.64 35 mm SOLID AgroB.64 40 mm
Condicions de prova STC STC STC STC
Potència nominal 445 W 445 W 300 W 300 W
Dades elèctriques @STC
Potència màxima (Pmax), W 445 445 300 300
Voltage a la potència màxima (Vmpp), V 29,40 29,40 19,60 19,60
Corrent a la potència màxima (Impp), A 15,14 15,14 15,31 15,31
Circuit obert Voltage (Voc), V 34,40 34,40 22,78 22,78
Corrent de curtcircuit (Isc), A 15,79 15,79 15,97 15,97
Dades tèrmiques
Interval de temperatura de funcionament -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F) -40 °C ÷ 85 °C (-40 °F ÷ 185 °F)
Coeficient de temperatura de Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Coeficient de temperatura de Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Coeficient de temperatura de Isc +0,036%/°C (°F) +0,036%/°C (°F) +0,045%/°C (°F) +0,045%/°C (°F)
Dades de mida i pes
Longitud 1762 mm 1762 mm 1762 mm 1762 mm
Amplada 1134 mm 1134 mm 1134 mm 1134 mm
Gruix 35 mm 40 mm 35 mm 40 mm
Pes 35 kg 36 kg 35 kg 36 kg
Mètode de muntatge
Reference to the chapter 3.3
Altres
Corrent invers màxim, A 30
Fire    class, IEC 61730/UL 61730 A/Tipus II
Volum màxim del sistematage, V 1500

Table 11.Electrical and mechanical parameters table.

  • The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
  • Tots els panells SoliTek SOLID PV corresponen a la classe de seguretat elèctrica II.

Exempció de responsabilitat

  • Atès que SoliTek és impossible controlar la instal·lació, el funcionament, l'aplicació i el manteniment del sistema fotovoltaic d'acord amb aquesta instrucció. SoliTek no assumeix cap responsabilitat i declina expressament la responsabilitat per qualsevol pèrdua, dany o despesa derivada d'aquesta instal·lació, operació, ús o manteniment o de qualsevol manera relacionada amb ella.
  • SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
  • The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.

www.solitek.eu

Preguntes freqüents

  • Q: What should I do before installing the PV modules?
    • A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
  • Q: Can I install the PV modules myself without professional training?
    • A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
  • Q: What happens if I don’t follow the instructions in this guide?
    • A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
  • Q: Is it safe to work on a rooftop during installation?
    • A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
  • Q: How should I store the PV modules before installation?
    • A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.

Documents/Recursos

PDF thumbnailSOLID Series Solar Modules
Installation Guide · SOLID Series Solar Modules, SOLID Series, Solar Modules, Modules

Referències

Fes una pregunta

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Fes una pregunta

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.