1. Introducció
This manual provides essential information for the safe and efficient operation, installation, and maintenance of the TRANE 4TTA3060D4000DA ACC-12247 Commercial Central Air Conditioner Condenser. This unit is a 5-ton commercial condenser designed for specific applications. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures.
Informació de seguretat:
- Desconnecteu sempre l’alimentació abans de donar servei a la unitat.
- Installation and service should only be performed by qualified, licensed HVAC technicians.
- Ensure proper grounding and electrical connections as per local and national electrical codes.
- This unit operates on 460 Volt, 3-phase power. Incorrect voltage can cause severe damage or injury.
- Refrigerant R-410A is used in this system. Handle with care and follow all safety guidelines for refrigerants.
2. Configuració i instal·lació
The TRANE 4TTA3060D4000DA ACC-12247 condenser unit requires professional installation due to its commercial nature and specific electrical requirements. This unit has been previously installed but never started, indicating it is in 'as new' condition but requires proper commissioning.
2.1 Selecció del lloc
Choose a location that allows for adequate airflow around the unit and provides sufficient space for maintenance access. Ensure the mounting surface is level and capable of supporting the unit's weight.
2.2 Connexions elèctriques
This unit requires a 460 Volt, 3-phase electrical supply. All wiring must comply with local and national electrical codes. Incorrect voltage or phase connection will damage the unit and void the warranty. A dedicated circuit breaker is required.
2.3 Conduccions de refrigerant
Connect the refrigerant lines (liquid and suction) to the appropriate ports on the condenser. Ensure all connections are leak-free. The unit is shipped with a dry gas charge for testing and shipping purposes; it must be properly evacuated and charged with R-410A refrigerant by a certified technician during installation.

An image showing the exterior of the TRANE 4TTA3060D4000DA ACC-12247 commercial central air conditioner condenser unit. The unit is gray, rectangular with rounded corners, and features louvered panels on its sides for airflow. A fan grille is visible on the top surface, indicating the fan's location. The Trane logo is visible on one side.
3. Instruccions de funcionament
The TRANE 4TTA3060D4000DA ACC-12247 is a condenser unit, which is part of a larger central air conditioning system. It works in conjunction with an indoor evaporator coil and a thermostat to provide cooling. Operation is typically controlled by the building's central thermostat or building management system.
3.1 Inici inicial
- Ensure all electrical and refrigerant connections are secure and verified by a qualified technician.
- Verify the system has been properly evacuated and charged with the correct amount of R-410A refrigerant.
- Restore power to the unit at the main disconnect.
- Set the thermostat to a cooling mode and a temperature below the ambient temperature to initiate a cooling cycle.
- Monitor the unit for proper operation, including fan rotation and compressor engagement.
3.2 Funcionament normal
Once started, the condenser unit will cycle on and off as dictated by the thermostat's demand for cooling. The outdoor fan will draw air over the condenser coil to dissipate heat from the refrigerant.
4. Manteniment
Regular maintenance is crucial for the longevity and efficient operation of your TRANE condenser unit. All maintenance should be performed by a qualified HVAC technician.
4.1 Comprovacions rutinàries (mensuals/trimestrals)
- Neteja les bobines: Inspect and clean the outdoor condenser coils to remove dirt, leaves, and debris. Blocked coils reduce efficiency.
- Neteja els residus: Ensure the area around the unit is free of obstructions, vegetation, and debris that could impede airflow.
- Inspeccioneu les aspes del ventilador: Check for any damage or imbalance in the fan blades.
4.2 Servei professional (anual)
- Comprovació del nivell de refrigerant: Verify proper refrigerant charge. Low or high charge can impact performance and damage the compressor.
- Connexions elèctriques: Inspect all electrical connections for tightness and signs of wear.
- Compressor Health: Check compressor operation, including voltage i amperage.
- Comprovació del condensador: Test the start and run capacitors.
- Drenatge: Ensure proper condensate drainage from the indoor evaporator coil (part of the overall system).
5. Solució De Problemes
This section provides general troubleshooting guidance. For complex issues or repairs, always contact a qualified HVAC technician.
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no comença | No power; Thermostat setting incorrect; Blown fuse/tripped breaker; Safety switch tripped | Check power supply; Adjust thermostat; Reset breaker/replace fuse; Consult technician for safety switch |
| Unit runs but no cooling | Low refrigerant; Dirty coils; Compressor issue; Fan motor issue | Contact technician for refrigerant charge; Clean coils; Consult technician for compressor/fan motor repair |
| Loud noises from unit | Loose fan blades; Compressor issue; Debris in fan | Inspect fan; Contact technician for compressor diagnosis; Remove debris |
| High energy bills | Dirty coils; Low refrigerant; Improper sizing; Poor insulation | Perform routine maintenance; Consult technician for system optimization |
6. Especificacions
Detailed specifications for the TRANE 4TTA3060D4000DA ACC-12247 Commercial Condenser Unit:
- Model: 4TTA3060D4000DA
- Número d'estoc: ACC-12247
- Tipus d'equip: Condensador
- Cooling Size: 5 tones
- Tipus de refrigerant: R-410A
- Elèctrica: 460 Volt, 3-Phase
- Any de fabricació: 2017
- Tipus de condensador: Straight Cool
- Equipment Condition: As New (previously installed but never started)
- Fabricant: TRANE
- Pes del producte: 260 lliures (117.93 kg)
- Tipus d'aplicació: Comercial
- ASIN: B07L392HFM
7. Garantia i Suport
For specific warranty information regarding your TRANE 4TTA3060D4000DA ACC-12247 Commercial Condenser Unit, please refer to the documentation provided at the time of purchase or contact your authorized Trane dealer or the seller directly. Warranty terms typically cover manufacturing defects and may vary based on installation and registration.
For technical support, service, or to locate an authorized Trane service provider, please visit the official Trane website or contact their customer service line. Always provide your model and serial number when seeking support.