Trane VAL12000

Trane VAL12000 OEM Thermostatic Expansion Valve

Model: VAL12000 / VAL-12000

Marca: Trane

1. Producte acabatview

The Trane VAL12000 / VAL-12000 is an Original Equipment Manufacturer (OEM) thermostatic expansion valve designed for use in various Trane chiller systems. This component plays a crucial role in the refrigeration cycle by controlling the amount of refrigerant flowing into the evaporator, ensuring efficient heat exchange and system performance.

It is a direct replacement for or supersedes models VAL-12000, VAL012000, VAL08573, VAL-8573, and VAL8573.

Component OEM de Traneamp

Figure 1: Illustrative stamp indicating Trane OEM Component. Actual product appearance may vary.

Commonly Used In:

  • Various Trane Chillers: Rotary Chillers, RTAC Chillers, BCVC Chillers
  • Specific Rotary Chiller Models: RTAC120, RTAC135, RTAC140, and others.

2. Especificacions

FabricantTrane
Número de partVAL12000
Número de model de l'articleVAL12000
Tipus de vàlvulaVàlvula d'expansió termostàtica (TXV)
Connexions1.387 ODS (Outlet Diameter Size) x 2.125 OD (Overall Diameter); M12 Input
Pes de l'articleAproximadament 5 lliures
Quantitat de paquet d'articles1
ASINB07ZWHPJS6
Data de primera disponibilitat1 de novembre de 2019

Nota: Les especificacions estan subjectes a canvis sense previ avís. Consulteu sempre l'etiqueta del producte per obtenir la informació més precisa.

3. Pautes d'instal·lació

Installation of the Trane VAL12000 expansion valve should only be performed by qualified HVAC technicians. Improper installation can lead to system malfunction, refrigerant leaks, and potential safety hazards. Always follow industry best practices and local codes.

3.1 Precaucions de seguretat

  • Ensure the system is de-energized and depressurized before beginning any work.
  • Wear appropriate Personal Protective Equipment (PPE), including safety glasses and gloves.
  • Handle refrigerants with care, following all safety guidelines.
  • Assegureu-vos una ventilació adequada a la zona de treball.

3.2 Passos d'instal·lació (generals)

  1. Preparació del sistema: Isolate the section of the refrigeration system where the valve is to be installed. Recover any refrigerant according to environmental regulations.
  2. Treure la vàlvula antiga: Carefully disconnect and remove the existing expansion valve, noting its orientation and connections.
  3. Prepare New Valve: Inspect the new VAL12000 valve for any damage. Ensure all connection points are clean and free of debris.
  4. Connect Valve: Install the new valve, ensuring proper alignment and secure connections. Use appropriate brazing or flaring techniques as required by the system design. Pay close attention to the M12 input and ODS connections.
  5. Thermal Bulb Placement: Securely attach the thermal bulb to the suction line in the correct location, typically just after the evaporator outlet, ensuring good thermal contact. Insulate the bulb to prevent ambient temperature interference.
  6. Comprovació de fuites: After installation, perform a thorough leak check using an appropriate leak detection method.
  7. Evacuació i càrrega: Evacuate the system to a deep vacuum to remove non-condensables and moisture. Recharge the system with the correct type and amount of refrigerant as specified by the chiller manufacturer.
  8. Engegada del sistema: Slowly bring the system back online and monitor its performance to ensure proper operation of the expansion valve.

For detailed, system-specific installation instructions, refer to the service manual of the Trane chiller unit in which this valve is being installed.

4. Funcionament

The Trane VAL12000 is a thermostatic expansion valve (TXV) that automatically regulates the flow of liquid refrigerant into the evaporator based on the superheat of the refrigerant vapor leaving the evaporator. Its primary function is to maintain a constant superheat, ensuring the evaporator is fully utilized without allowing liquid refrigerant to return to the compressor.

The thermal bulb, sensing the temperature of the suction line, transmits pressure to the diaphragm within the valve. This pressure, balanced against the evaporator pressure and spring pressure, modulates the valve's opening. This dynamic control optimizes system efficiency and protects the compressor from liquid slugging.

5. Manteniment

The Trane VAL12000 expansion valve is a robust component designed for long-term reliability. While it generally requires minimal direct maintenance, its optimal performance is dependent on the overall health and cleanliness of the refrigeration system.

5.1 Pràctiques recomanades

  • Neteja del sistema: Ensure the refrigeration system remains free of contaminants (moisture, acids, debris) which can cause corrosion or blockages within the valve. Regular filter dryer replacement is crucial.
  • Refrigerant Quality: Use only the specified type and quality of refrigerant.
  • Seguiment del rendiment: Periodically monitor system superheat and subcooling. Deviations can indicate issues with the expansion valve or other system components.
  • Detecció de fuites: Regularly check for refrigerant leaks around valve connections.

Any adjustments or repairs to the expansion valve or refrigeration system should be performed by certified HVAC professionals.

6. Solució De Problemes

Troubleshooting issues related to an expansion valve often involves diagnosing overall system performance. The following are common symptoms that might indicate an issue with the expansion valve, though they can also be caused by other system components.

SímptomaPossible Cause (Valve Related)Acció
Sobreescalfament alt / Pressió d'aspiració baixaValve restricted or stuck closed; thermal bulb lost charge or improperly installed.Check thermal bulb contact and insulation. Inspect valve for blockages. Consider valve replacement if faulty.
Low Superheat / High Suction Pressure (Flooding)Valve stuck open; thermal bulb improperly installed or sensing incorrect temperature.Verify thermal bulb placement. Check for external bulb damage. Consider valve replacement if faulty.
Fluctuating Suction Pressure / SuperheatIntermittent valve operation; moisture in system causing ice formation at valve orifice.Check for system contaminants. Replace filter dryer. Evacuate and recharge system.
Compressor Short CyclingImproper refrigerant flow due to valve issue, leading to low pressure cutout.Diagnose refrigerant charge and valve operation.

Important: Troubleshooting refrigeration systems requires specialized knowledge and tools. Always consult with or hire a qualified HVAC technician for diagnosis and repair.

7. Garantia i Suport

As an OEM component, the Trane VAL12000 expansion valve is typically covered under the warranty terms provided by Trane for their chiller systems or by the distributor from whom it was purchased. Specific warranty details, including duration and coverage, may vary.

For warranty claims, technical support, or to order replacement parts (such as MOD02686 for a stepper motor or MOD02688 for a cable, if applicable to your system), please contact your authorized Trane distributor or a certified HVAC service provider.

Fabricant: Trane

Contacte: Refer to your local Trane representative or the official Trane website for service and support information.

Documents relacionats - VAL12000

Preview Instruccions d'instal·lació del kit del programa de servei de renovació Trane RTWD/RTUD
Instruccions d'instal·lació del kit del programa de servei Trane R'newal per a refrigeradors RTWD i RTUD, que detallen la ubicació de les peces, els avisos de seguretat, les preocupacions mediambientals i les avaries dels components.
Preview Catàleg complet de disseny de sistemes d'aigua refrigerada de Trane
Catàleg complet de Trane per dissenyar sistemes avançats d'aigua refrigerada. Aquesta guia detalla els components del sistema, els principis de disseny més moderns, les configuracions i els criteris de selecció per a refrigeradors, torres de refrigeració, bombes i vàlvules de control. Se centra en aconseguir l'eficiència, la fiabilitat i la rendibilitat en aplicacions de climatització comercials i industrials, incloent-hi informació sobre el control de plantes de refrigeració Tracer i l'assistència de disseny de Trane.
Preview Instruccions d'instal·lació de la modernització Trane AFDR per a refrigeradors RTHD
Guia d'instal·lació completa per al Trane AFDR Retrofit Adaptive Frequency Drive™ refrigerat per aire per a refrigeradors RTHD. Cobreix la seguretat, les condicions ambientals, els detalls del model i els procediments d'instal·lació pas a pas per a personal qualificat.
Preview Instruccions d'instal·lació de l'encesa Trane KIT03033USA
Instruccions d'instal·lació detallades per a l'encenedor Trane KIT03033USA, que inclouen avisos de seguretat, consideracions mediambientals i procediments pas a pas per a personal qualificat.
Preview Trane Air-Fi™ Wireless Communications Sensor (WCS) Quick Reference Guide
This guide provides quick reference information for the Trane Air-Fi™ Wireless Communications Sensor (WCS), detailing how to adjust room temperature, system settings, fan speed, manage occupancy, and understand error codes. It includes safety warnings and battery life indicators.
Preview Trane Building Automation System (BAS) and HVAC Components Price List
Comprehensive price list for Trane Building Automation Systems (BAS), HVAC equipment, and related components, including controllers, sensors, chillers, air handlers, and accessories. Details product codes, model numbers, and pricing for commercial and industrial applications.