1. Introducció
This instruction manual provides essential information for the safe and efficient use of your Trane MOT18949 1/2HP 115V 1075RPM 48 PSC Motor. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper handling and to prevent potential hazards. This motor is designed for specific HVAC applications as an OEM component.

Figure 1: Trane MOT18949 1/2HP 115V 1075RPM 48 PSC Motor. This image shows the motor from an angled perspective, highlighting its cylindrical body, cooling fins, shaft, and electrical wiring harness.
2. Informació de seguretat
ADVERTIMENT: Failure to follow these safety instructions could result in electric shock, fire, serious injury, or death.
- Always disconnect power before installing, servicing, or cleaning the motor.
- La instal·lació i el manteniment només els ha de dur a terme personal qualificat.
- Assegureu-vos que tot el cablejat compleixi els codis elèctrics locals i nacionals.
- No feu funcionar el motor si està danyat o si hi falta algun component.
- Keep hands, tools, and clothing away from moving parts.
- Assegureu-vos de posar a terra correctament per evitar descàrregues elèctriques.
- Utilitzeu només peces de recanvi especificades.
3. Configuració i instal·lació
This motor is an OEM component designed for integration into specific Trane and American Standard HVAC systems. Refer to the specific equipment's service manual for detailed installation procedures.
3.1 Comprovació prèvia a la instal·lació
- Verify that the motor specifications (HP, RPM, Voltage) match the requirements of the equipment.
- Inspeccioneu el motor per detectar qualsevol dany durant el transport.
- Assegureu-vos que totes les eines i els equips de seguretat necessaris estiguin disponibles.
3.2 Muntatge
- Mount the motor securely using the resilient rings provided, ensuring proper alignment with the driven component (e.g., fan blower).
- Avoid overtightening mounting bolts, which can distort the motor housing.
3.3 Connexió elèctrica
- Connect the motor wiring according to the wiring diagram provided with the HVAC unit or the motor itself.
- Ensure the capacitor (15 MFD @ 370V) is correctly wired as this is a PSC (Permanent Split Capacitor) motor.
- Verificar la connexió a terra correcta.
- Double-check all connections for tightness and insulation.

Figure 2: Trane OEM Component Stamp. This image displays a circular stamp with "TRANE OEM COMPONENT" text, indicating the authenticity of the part.
4. Instruccions de funcionament
Once installed and wired correctly, the motor's operation is typically controlled by the HVAC system it is integrated into. There are no direct user controls on the motor itself.
- Posada en marxa inicial: After installation, restore power to the HVAC unit. The motor should start and operate smoothly when called upon by the system's thermostat or control board.
- Funcionament normal: The motor is designed for continuous operation within its specified parameters. Monitor for unusual noises or vibrations during initial operation.
- Tancament: The motor will cease operation when the HVAC system's demand is met or when power is removed.
5. Manteniment
Regular maintenance ensures the longevity and efficient operation of your Trane motor. Always disconnect power before performing any maintenance.
- Neteja: Periodically clean the exterior of the motor to remove dust and debris that can impede cooling. Use a soft brush or compressed air. Do not use water or solvents directly on the motor.
- Inspecció: Annually inspect the motor for signs of wear, such as loose wiring, corrosion, or unusual bearing noise. Check the mounting for security.
- Lubricació: This motor features sleeve bearings. Consult the specific HVAC unit's service manual for lubrication requirements, if any. Many modern motors are permanently lubricated.
6. Solució De Problemes
If the motor is not functioning as expected, refer to the following common issues and their potential solutions. For complex problems, contact a qualified HVAC technician.
| Problema | Causa possible | Solució |
|---|---|---|
| El motor no arrenca. | No power, faulty capacitor, open circuit, seized bearing. | Check power supply. Test/replace capacitor. Inspect wiring. Check for obstructions or bearing failure. |
| El motor s'escalfa. | Overload, insufficient ventilation, low voltage, problemes de rodaments. | Verify load is within motor rating. Ensure clear airflow. Check supply voltage. Inspect bearings. |
| Sorolls o vibracions inusuals. | Loose mounting, worn bearings, unbalanced load. | Tighten mounting bolts. Inspect/replace bearings. Check fan/blower for balance. |
| Motor hums but does not turn. | Faulty capacitor, seized shaft, wiring error. | Test/replace capacitor. Check for obstructions preventing shaft rotation. Verify wiring. |
7. Especificacions
The following are the key specifications for the Trane MOT18949 motor:
- Número de model: MOT18949
- Potència (HP): 1/2 CV (0.5 cavalls de potència)
- Voltage: 115 Volts
- Freqüència: 60 Hz
- Fase: 1 Fase
- RPM: 1075 RPM
- Tipus de motor: PSC (Permanent Split Capacitor)
- Mida del marc: 48 FRM
- Rotació: CCW (Counter-Clockwise)
- Rodaments: Coixinets de màniga
- Capacitor Requirement: 15 MFD @ 370V
- Material: Copper (windings)
- Pes de l'article: Approximately 150 Pounds (Note: This weight seems unusually high for a 1/2HP motor, please verify with product documentation if critical.)
- Fabricant: Trane
8. Garantia i Suport
As an OEM component, the warranty for the Trane MOT18949 motor is typically covered under the warranty of the complete HVAC system it is installed in, or by Trane's standard parts warranty. Specific warranty terms and conditions may vary.
For warranty claims, technical support, or service inquiries, please contact your authorized Trane dealer or the manufacturer directly. Ensure you have your product model number (MOT18949) and the serial number of the HVAC unit available when contacting support.
Fabricant: Trane